           D A T A S H E E T                     S  G - 6  R 1 P 5 K
           Models                                   5K
           Input DC
           R  o c e  m m  n e  d e  m   d  P   . x a  p   V  o w  r e  k   5 . 7  W
           Max. input voltage                      600 V
           Rated voltage                           330 V
           Start-up voltage                        120 V
           MPPT voltage range                      90-520 V
           Max. input current                     14 A / 14 A
           Max. short circuit current             22 A / 22 A
           M P P  n   T  u m b  / r e  M  n i   . x a  p  n i r t s   t u  n   s g  u m b  r e  2 / 2
           Output AC
           Rated output power                      5 kW
           Max. apparent output power              5 kVA
           Max. output power                       5 kW
           Rated grid voltage                    1/N/PE, 220 V / 230 V
           Rated grid frequency                   50 Hz / 60 Hz
           Rated grid output current              22.7 A / 21.7 A
           Max. output current                     25.0 A
           Power factor                        >0.99 (0.8 leading - 0.8 lagging)
           THDi                                     <3%

                                                   97.7%
                                                   97.1%
           Protection
           DC reverse-polarity protection           Yes
           Short circuit protection                 Yes
           Output over current protection           Yes
           Surge protection                         Yes
           Grid monitoring                          Yes
           Anti-islanding protection                Yes
           Temperature protection                   Yes
              e t a r g e t n I  F A   d  D (   I C  a f - c r a   C  o i t c e t o r p   t i u c r i c   t l u  ) n  (1)   s e Y
           Integrated DC switch                    Optional
           General Data
           Dimensions (W*H*D)                    310*543*160 mm
           Weight                                  12 kg
           Topology                              Transformerless
           Self-consumption (night)                <1 W
           O p  n i t a r e  a   g  m  e t   t n e i b  m p  a r   e r u t a r e  n  e g  C ° 0 6 +   ~   5 2 -
           Relative humidity                       0-100%
           Ingress protection                       IP66
           Cooling concept                       Natural convection
           Max. operation altitude                 4000 m
                               G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 /
           Grid connection standard
                              UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
              E / y t e f a S  M  a t s   C  n d  d r a  E I  E / C  E I   , 2 - / 1 - 9 0 1 2 6   N  E / C  3 - / 2 - 6 - 0 0 0 1 6   N
           Features
           DC connection                          MC4 connector
           AC connection                        Quick connection plug
           Display                                  LCD
           Communication                       RS485, Optional: Wi-Fi, GPRS